RemoteTx Manual
remotetx.net

Connecting loggers

Loggers talk to EasyConnect as if it were a Kenwood TS-480, over TCP or a COM port. Several programs can be connected at once (N1MM and WSJT-X together, for example), and each gets its own auto-information setting.

N1MM Logger+#

  1. Start EasyConnect. The CAT server starts on 127.0.0.1:12500.
  2. In N1MM: Config → Configure Ports, Mode Control, Winkey, etc. → Hardware.
  3. Port TCP, Radio TS-480, address 127.0.0.1:12500.
  4. Click Set if you want PTT via Radio Command (sent as TX; / RX;).
  5. Operate normally: tune, change bands and modes, split, click spots, send CW. Watch the EasyConnect log.

CW sent from N1MM (KY text) goes to the radio's keyer on radios that support it (see Supported radios).

WSJT-X#

In File → Settings → Radio:

SettingValue
RigKenwood TS-480
Serial Port127.0.0.1:12500 (type it in; use the IP, not localhost)
PTT MethodCAT

Then click Test CAT. With the FT-991/991A, set Split Operation to Fake It.

✅Tip

For FT8 you don't need WSJT-X at all: the RemoteTx FT8 tab does the job in the browser, and EasyConnect still lets loggers see it as WSJT-X. See FT8 to loggers.

HRD Logbook#

HRD Logbook (and DM780) don't use TS-480 CAT: they talk to HRD Rig Control on port 7809. EasyConnect can take HRD Rig Control's place. See HRD Logbook rig control.

Programs that only use COM ports#

Some loggers can only talk to a radio on a COM port. EasyConnect can answer CAT on a COM port too, using com0com, a free driver that makes a pair of virtual COM ports joined by a virtual cable.

  1. In com0com's setup, create a pair, e.g. COM10 ↔ COM11.
  2. In EasyConnect, under CAT on COM ports, choose COM10 for COM port 1 (it's ticked and started as soon as you choose it), with Auto baud. The COM 1 pill shows the port.
  3. In the logger: radio Kenwood TS-480, port COM11, any baud (19200 is usual), 8-N-1.

A second COM-only program can use COM port 2 with its own pair (e.g. COM12 here, COM13 in the program). TCP and COM clients can be connected at the same time.

Auto baud listens to what arrives and tries 19200, 9600, 38400, 57600, 115200 and 4800 until the commands read correctly, then locks on (the pill shows (auto) and the log says CAT at … baud). With com0com's default settings the speed doesn't matter at all. You can also pick a fixed speed.

Loggers on another computer#

By default EasyConnect only accepts connections from the same computer. To use a logger on another PC:

  1. Set CAT TCP host to 0.0.0.0 and click Apply & restart.
  2. In the logger, use this computer's LAN address (shown in the header, click to copy) with port 12500.
  3. Allow EasyConnect through the firewall (Windows: when asked, or with Allow through Windows Firewall; macOS: allow incoming connections when asked).

Checking what a logger does#

Every command a logger sends is listed in Commands seen and in the Log. Commands EasyConnect doesn't handle show as UNKNOWN and get ?; back. Use Save… to keep a copy when reporting a problem. Tick Hide routine polls to hide the constant frequency and mode reads.

© RemoteTx® · remotetx.net · Manual built 2026 · Updated 2026-11-19